博世BOSCH-火灾报警控制器,4防区24V,红色外壳-FPD-7024

厂家报价:面议 产品状态:(在产)

Fourinitiatingzones(expandabletoeight)withupto20two‑wiresmokedetectorsperzoneProgrammablethroughkeypadsorremoteprogrammingsoftware(RPS)throughaConett...

产品品牌: 博世BOSCH
产品类别: 产品中心
咨询 加入收藏 我要评价
咨询
所在单位:*
姓名:*
手机:*
职位:
邮箱:*
其他联系方式:
咨询内容:
验证码:
不能为空 验证码错误
确定
博世(上海)安保系统有限公司(BOSCH)

厂商介绍: 博世(上海)安保系统有限公司(BOSCH)是全球领先的安防、会议和广播产品研发、制造、服务商及相关解决方案与服务的提供商。博世Bosch安防通讯产品线覆盖博世Bosch视频监控、博世Bosch入侵报警系统、博世Bosch会议系统、博世Bosch公共广播和语音报警、博世Bosch火灾报警系统、博世Bo... [详细]

经销商 联系方式 价格
博世BOSCH 400-8310-669、021-2218 1111 面议
Line impedance for ground fault detection (Option Bus, conventional input, NAC, secondary power circuit, MUX Bus, AUX power, SMK power) 10kΩ
Power (Input) 120V 60Hz 1.4A or 230\240V 50Hz, 0.7A
Power (Auxiliary) 17 to 31VFWR, unfiltered, 1.0A
Power (Smoke)1 20.4 to 28.2VDC nominal, filtered, 1.0A.
Power (Option Bus) 12VDC nominal, 500mA
Power (Notification Appliance Circuit [NAC])2 Each NAC has 24VFWR nominal, unfiltered power with up to 2.5A capacity (but limited by overall 4.0A capacity)
Power (Optional Standby Batteries) Two 12V (in series), 7Ah to 40Ah
NACs Line Impedance (voltage loss) 1.5V
Recommended Manufacturers3 Power Sonic: PS-1270, PS-12170, PS-12180YUASA: NP7-12, NPG18-12
1 For compatible smoke detection devices, see also the FPD‑7024 Smoke Detector Compatibility List.2 For compatible NAC devices, see also the FPD‑7024 NAC Compatibility List3 If other manufacturers or battery types are used, ensure that the battery or batteries can handle an initial charge current of at least 1.7 A.
Temperature (operating and storage) +32°F to +120°F (0°C to +49°C)
Wiring ClassB or ClassA
Notification patterns Configurable for steady, pulsing, California March, Temporal (ANSI) code 3, synchronized Wheelock, synchronized Gentex, and synchronized System Sensor.
Local (on-board) The main control panel includes Three FormC relays. The relay contacts are rated at 5A, 28VDC. No over current limiting is performed on the contacts of the relays. The default selection for the relays is to indicate general alarm (relay 1), general system trouble (relay 2), and supervisory (relay 3). By using point or zone mapping, they can be programmed to activate in a wide variety of conditions.
Remote1 Eight Form C relay outputs are provided by a D7035 Remote Relay Module. The module connects to the FPD‑7024 through the option bus. The outputs are fully programmable, exactly as the local relays are programmed. Each output operates independently of the other seven to provide complete flexibility. Communication with the D7035 is supervised. Contact Rating: 5A at 28VDCNumber of Modules: two units maximum.
1 For wiring requirements, see Option bus wiring requirements.