NetPA Series |
|
Audio |
Crosstalk |
>75 dB @ 1 kHz |
|
Audio input |
Number/signal type |
|
NetPA 502 AT |
1 stereo or 2 mono |
NetPA 1001-70V AT |
1 mono |
Connectors |
1 RJ-45 |
Maximum level |
0 dBFS (digital) |
|
Audio processing |
D/A conversion |
24 bit, selectable sampling rate |
|
AT ports — audio transport |
Transmission |
Dante/AES-67, software selectable |
Connector |
1 RJ-45 connector, 1-port 100 Mbps to Dante interface |
Inputs |
|
NetPA 502 AT |
2 channels Rx |
NetPA 1001-70V AT |
1 channel Rx |
Audio format |
24-bit uncompressed, selectable at 44.1,48, 88.2, and 96kHz sampling rate |
Latency |
Deterministic, based on user selection: 2.0 ms (default), 5.0 ms |
|
Audio line output |
Number/signal type |
|
NetPA 502 AT |
2 channels, balanced/unbalanced |
NetPA 1001-70V AT |
1 channel, balanced/unbalanced |
Connectors |
|
NetPA 502 AT |
(1) 3.5 mm captive screw connector,6 pole |
NetPA 1001-70V AT |
(1) 3.5 mm captive screw connector,3 pole |
Impedance |
50 ohms unbalanced, 100 ohms balanced |
Maximum level (at 0 dBFS digital input) |
>+15 dBu balanced; +9 dBu unbalanced |
Frequency response |
20 Hz to 20 kHz, ±1 dB |
THD + Noise |
0.03% @ 1 kHz at nominal level, 0.3% @ 20 kHz at nominal level |
S/N |
>90 dB, at maximum output (unweighted) |
NOTE |
0 dBu = 0.775 Vrms, 0 dBV = 1 Vrms, 0 dBV ≈ 2 dBu |
|
|
Audio speaker output |
Number/signal type |
|
NetPA 502 AT |
2 channels, 4 or 8 ohms |
NetPA 1001-70V AT |
1 channel, 70 V |
Connectors |
|
NetPA 502 AT |
(1) 5.08 mm screw lock captive screw connector, 4 pole |
NetPA 1001-70V AT |
(1) 5.08 mm screw lock captive screw connector, 2 pole |
NOTE |
These connectors accept wires of 22 AWG to 12 AWG. |
|
Load impedance |
|
NetPA 502 AT |
4 ohms minimum |
NetPA 1001-70V AT |
50 ohms minimum |
Amplifier type |
Class D |
Output power |
|
NetPA 502 AT |
50 watts rms per channel, 4 ohms, 1 kHz, 0.1% THD 25 watts rms per channel, 8 ohms, 1 kHz, 0.1% THD |
NetPA 1001-70V AT |
100 watts rms, 70 V, 1 kHz, 0.1% THD |
Frequency response |
|
NetPA 502 AT |
20 Hz to 20 kHz, +1/-3 dB @ 1 watt |
NetPA 1001-70V AT |
20 Hz to 20 kHz, +1/-3 dB @ 1 watt |
THD + Noise |
<0.1% @ 1 kHz, 3 dB below clipping |
S/N |
>90 dB, 20 Hz - 20 kHz, unweighted |
High pass filter |
|
NetPA 1001-70V AT |
80 Hz, 12 dB per octave rolloff for 70 V line output (switch selectable) |
|
Communications — amplifier |
Control port |
(1) 3.5 mm captive screw connector,2 pole |
Pin configurations |
|
Standby power control (contact closure) |
Pin1 = standby, pin2 = Gnd |
|
General |
Power supply |
Internal Input: 100-240 VAC, 50-60 Hz, 0.5 A |
Power consumption and thermal dissipation |
|
NetPA 502 AT
|
115 VAC, 60Hz |
230 VAC, 50Hz |
AC Line Current |
AC Power Consumed |
Thermal Dissipation |
AC Line Current |
AC Power Consumed |
Thermal Dissipation/ |
Condition |
A |
W |
W |
BTU/hr |
A |
W |
W |
BTU/hr |
Active (1/8 power), all channels driven |
8Ω |
0.3 |
14.6 |
8.3 |
28 |
0.2 |
17 |
10.7 |
36 |
4Ω |
0.4 |
22.3 |
9.8 |
33 |
0.3 |
24 |
11.7 |
40 |
Quiescent (idle) |
0.1 |
7.4 |
7.4 |
25 |
0.1 |
9.9 |
9.9 |
34 |
Standby |
<0.1 |
<2 |
<2 |
<6 |
<0.1 |
<2 |
<2 |
<6 |
|
NetPA 1001-70V AT
|
115 VAC, 60Hz |
230 VAC, 50Hz |
AC Line Current |
AC Power Consumed |
Thermal Dissipation |
AC Line Current |
AC Power Consumed |
Thermal Dissipation |
Condition |
A |
W |
W |
BTU/hr |
A |
W |
W |
BTU/hr |
Active (1/8 power), all channels driven |
70 V |
0.4 |
22.7 |
10.2 |
35 |
0.3 |
24.1 |
11.6 |
39 |
Quiescent (idle) |
0.1 |
7.6 |
7.6 |
26 |
0.1 |
9.2 |
9.2 |
31 |
Standby |
<0.1 |
<2 |
<2 |
<6 |
<0.1 |
<2 |
<2 |
<6 |
|
Temperature/humidity |
Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing Operating: +32 to +104 °F (0 to +40 °C) / 10% to 90%, noncondensing |
Cooling |
Convection, no vents, with internal heat sink |
Protection |
Clip limiting, thermal, short circuit, DC output |
Indication |
Limiter/Protect LED indicates the onset of clip limiting, thermal cycling, or short circuit |
Mounting |
|
Rack mount |
Yes, with optional 1U rack shelf |
Furniture mount |
Yes, with optional under-desk mounting kit |
Enclosure type |
Metal |
Enclosure dimensions |
1.7" H x 8.7" W x 9.5" D (1U high, half rack wide) (4.3 cm H x 22.1 cm W x 24.1 cm D) |
Product weight |
|
NetPA 502 AT |
2.6 lbs (1.2 kg) |
NetPA 1001-70V AT |
2.6 lbs (1.2 kg) |
Regulatory compliance |
BSEN 60065, CE, C-tick,c-UL, EN 55103-1, EN 55103-2, ENERGY STAR®, FCC Class B, ICES, IEC 60065,RoHS,UL, UL 60065,VCCI Class B, WEEE. |
Product warranty |
3 years parts and labor |
Everlast power supply warranty |
7 years parts and labor |
NOTE |
All nominal levels are at ±10%. |
|
NOTE |
Specifications are subject to change without notice. |
|
(4536-D8) |